Chlorinator – Municipal Water Disinfection

Tiaano® India an ISO 9000 organisation - designing, manufacturing, supplying and commissioning on-site Electro Chlorinators for disinfection of drinking water in various Water boards like Public Health Organisation, Public Works Departments, Corporation, Municipalites and  Panjayats.

Electro Chlorinators are installed either directly by Tiaano through dealers. Bombay Municipal Corporation, Tamilnadu Corporations, Kerala Corporations, Kolkata Corporations, Gujarat Corporations, Indian Railways are our few regular customers. In addition  to the Indian supply, we are also exporting the plants over 60 countries.

Disinfection capacity of our standard ECU is 300,000 litres per day by 2 ppm of available Chlorine, suitable for major Public Health Organisation, Public Works Departments and  Panjayats.  Our experience on custom-built ECU for Corporations, Municipalities, light and heavy industrial applications are 50 kgs per hour / 1200 kgs per day (disinfection capacity of 600 MLD).

Our chlorinators generate hypo with the highest chlorine concentration that is economically possible, for example 8000 ppm by Brine (Fresh Water + Salt) both continuous and batch type Systems; 3 ppm by Swimming Pool (online continuous) Systems; 2 ppm by fresh water (online continuous) systems.

According to the client’s specification, our systems are fail-safe and interlock controlled either locally or by remote; They are designed for both safe and hazardous area optionally with full certification; with acid cleaning system or acid free self-cleaning system like reverse polarity and high flow velocity CTE construction. 

For further details on capacity and  models, please visit our site www.ecanode.com/Chlorinators.aspx Eclosed data sheet on the standard ECU is self explanatory. Request you to go through them same and feel free to call us / send us your enquiry for our quality quote.   Dealer’s equiries are solicited.



for more www.tiaano.com


December 18, 2015

CHEMICAL STORAGE TANK (COMPOSITE)

We design & manufacturing of vertical and horizontal chemical storage tanks made from solid, cladded or lined exotic metals like Titanium, Tantalum, Niobium, Zirconium, Duplex & Super Duplex Steel, Nickel & Nickel alloys like Hastelloy, Monel, and Inconel etc.  We makes the tanks for Anolyte storage, Catholyte storage, Caustic Storage, Depleted Brine storage, HCL Storage,  Sulphuric acid (H2SO4)  storage, Sodium hydroxide storage, Brine recovery tanks, Filtration Tanks, Chemical mixing tanks, Nuclear Waste Recovery and any corrosive liquid storage tanks.
For more details please visit www.fibtec.net

FACTORY MOLDED SEWAGE TREATMENT SYSTEM

“Comp-STS”, a factory modules (packaged) Composite sewage treatment system  is  comprehensive MBBR (Moving Bed Biofilm Reactor) based independent plant,  consisting of composite tank with anoxic, aeration and sludge recycling chambers, blowers, filters, dissolved oxygen meter and online electro-chlorinator. The treated water from the system is clear & disinfected.

for more details please visit: www.fibtec.net 

COMPOSITE (FIBRE) STORAGE TANK TECHNOLOGITES

Fibtec, Chennai, India is a unit of M/s. Ti Anode Fabricators Pvt. Ltd. (Tiaano®) – an ISO 9000 - 2008 Company engaged in designing, manufacturing, testing & supply of all type of Composite Tanks. We have the capacity of produce up to 50,000 litre water tanks.  Over 700 installations all over the world and  customers are supported through an international network of agents in 60 countries. 



Technologies:

The process of glass fibre filament winding is used for tank construction.  It’s high tensile strength resulting in high hoop tensile strength of the shell (250 MPa). Production process is tested as per BS 4994 standard.  

To prevent deflection due to soil overburden and vehicle load, the section modulus is increased by increasing the thickness of the shell and the L/D ratio is reduced by providing the stiffeners.   
To counter buoyancy force (assuming empty tank and fully saturated soil) Anchors are provided with nylon strap around the tank.    

Made from homogeneous type composite. It never allows percolation of even moisture from earth to tank or tank to earth. It is Impervious.  

Unlike thermoform resin like PVC or HDPE, the polymerised thermoset resin will not be affected by heat or weather conditions. 

For more please visit www.fibtec.net 


COMPOSITE WATER STORAGE TANK


“Comp-TNK”, the composite underground and above ground water   storage tanks is a unique product, developed to replace traditional R.C.C. sump or R.C.C. overhead tanks.  Homogeneous moulded and factory tested - it ensures Water tightness, Light weight, Corrosion resistance, Easy and Quick installation makes it builder’s choice even in water logged locations. 

Advantages:

Since the tank can be shifted from one place to another (while carrying out renovations / modifications to the building), it is having resale value. 

The tank can be supplied with inside partitions to meet the specific needs of the   clients. 

The outer diameter of the tank is 2300 mm, suitable for transporting by   commercial vehicles. 

The design life of the tank is 75 years. 

The tank is designed to be buried with soil cover of up to 1.5 meters and be  installed to counter the buoyancy is fully saturated soil condition. 

Weight of the tank is very less. so we can use this tank as over head tank also.

visit www.fibtec.net for more...



COMPOSITE BIO-SEPTIC TANK


“Comp-SEP”, a Factory manufactured Composite Underground Septic Tank comes with internal partition and leak proof (air tight)  construction. The insulating nature of the composite material maintains temperature inside the tank to allow the growth of the bacteria that digest solid waste. Its corrosion resistance property ensures the long life of the tank.  

Advantages:


FRP Bio septic Tank for Multiple Flats (person usage) both Grey & Black water. 

This system has been developed as per CPHEEO Manual (Central public Health   Environmental Engineering Organization) by on-site sanitation concept. 

The unit consists of two compartments made of FRP (Fiber reinforced Plastic).

First Tank is the collection Tank and another Tank is Treatment Tank (Biological Bacterial growth by Ball ring media). 

All the gases from the Tank are collected through vent pipe. 

The half Treated discharged from this is colorless; odorless confirms to the  pollution control Board norms.

Input BOD - 300-200 mg/l will be reduced to 130 - 100 mg/l by Biological Treatment.

Outlet water either used for Gardening or through soak pit by Ground water  recharging purpose.
Input pipe line connected through Bar Screen Chamber.

New FRP Bio septic Tank for Independent houses, for 5 Member usages per day.

more www.fibtec.net




Drinking Water Disinfection (Tiaano electrio Chlorinator)



for more www.tianode.com 


October 21, 2015

An innovative way to generate Sodium hypochlorite which minimizes the loss reactions.

Onsite Sodium hypo chlorite generators:
The last decade has seen the introduction to the market of a number of small     electrolysis cells for the generation of a low concentration (8gpl) hypochlorite; in many applications either type of cell could, in principle, be employed and the choice then depend on technological factors. In the water and effluent treatment industry, the common applications of onsite hypochlorite cells will include the treatment of sewage, the sterilization of water for food processes and hospital laundries, the treatment of water on board ships and for swimming pools, the treatment of cooling water at coastal power stations to prevent the growth of shell fish and seaweed in the pipes and the oxidation of cyanide ion in effluents.  Traditionally all these markets have been satisfied by liquid chlorine or high strength Sodium hypochlorite (100 to 120gpl), tanked from the large chlor-alkali plants, but there is now awareness to avoid the potential hazards with the        transportation and storage of these items.
Design considerations:
Electrolytic chlorinators can be designed to generate continuous or batch supplies depending on system needs. The loss reactions are to be reduced.
The losses while producing hypochlorite are due to anodic and auto catalytic       reactions, and cathodic reduction. In the cell design this is avoided by reduced     cathodic area and large flow rate than the design flow rate. Since these are being less practical, the present models are produced without consideration to these loss reactions resulting in low concentration hypo to less than the optimum        concentration. A hydrogen gas lift similar to the chlorate cells have proved much efficient, provided the circulation rate is much higher. Since typical potable water contains hardness, it is advisable to have least residence time in the cells by  increasing the velocity of circulation more than ten times the production rate.
Lift Coefficient:
A semi empirical formula to  express the hydrogen to lift one gallon of solution is
VH = 0.8[Ht /C log10 (Hs+34)/34]
Where VH is the volume of Hydrogen in ft 3, and C is constant (Lift coefficient characteristic to the type of cell design varying with total head and need to be                   experimentally determined)
Ht= Total ht in ft and Hs= Ht from the liquid surface to the bottom of the cell.
In the above equation all the terms are known excepting C and once it is experimentally found out the required variation in flow rate can be achieved by altering the Ht and Hs.
Example:

Supposing a 750 gm/hr cell lift 850 liters of solution187 (gallons)
VH =8.357 /187=0.0447 ft 3 Hydrogen for a Ht of 10 feet and Hs =9ft
Then C = 1743 approximately. With the lift coefficient the respective heights for a           required flow rate can be varied.
The flammability of limits based on the volume percent of hydrogen air at 14.7 Pisa are 4.0% and 75.0% respectively, hence to keep the concentrations below the threshold limit of 4.0% it should be diluted with air produced by blowers.
Controls:

With adequate control of dosing in to the treatment process it is imperative to maintain the desired residual. The residual analyzers DPD colrimetry or Amperometric                   instrument be located as close to the sampling point as possible. Tiaano® with the required instrumentation and control have installed various versions at Mumbai,     Trivandrum, and Chennai municipal corporations in India.

October 17, 2015

Removal of scale or calcium from water Animation - new technology





Removal of scale from water new concept.

It is applied for below intestries...



Beer and Beverage

  Hotel

  Hospital

  Industry

  Paper Mill

  Plastics Plants

  Sugar Mill

  Mines

  Power plants

  Steel Plants

  Hot water systems

  Kitchen water, hot and cold

  Laundry – hot water treatment

  Climate control – closed hot / cold water treatment

  Cooling towers



for more details please visit  http://www.scaleseparator.com/

Best Personal Diary book format for write all your details to rememberin...





This is the best personal diary for remembering you designed by Tiaano Vidyashrm have following details . 
1. FAMILY DETAILS
2. ANCESTORS
3. FAMILY DEITY
4. EMERGENCY PUBLIC SERVICE UTILITIES
5. CONTACT DETAILS OF IMPORTANT PERSONS
6. LOCATION OF IMPORTANT DOCUMENTS
7. BANK LOCKER & LIST OF CONTENTS
8. CREDIT CARD / DEBIT CARD
9. DETAILS OF EMPLOYMENT
10. DETAILS OF PROPERTY – PLOT, FLAT, RESIDENTIAL BUILDING
11. DETAILS OF JEWELS
12. DETAILS OF SILVER ARTICLES
13. DETAILS OF VEHICLES
14. VALUE OF ALL PROPERTIES OWNED
15. DETAILS OF HOUSE LIVED
16. BANK ACCOUNT DETAILS
17. DEPOSITS WITH BANKS / COMPANIES
18. INVESTMENTS IN MUTUAL FUND
19. SHARES (DEMAT)
20. INCOME TAX RECORD
21. LIFE INSURANCE COVER
22. HEALTH / MEDICAL INSURANCE
23. PERSONAL ACCIDENT INSURANCE
24. HOUSE HOLD INSURANCE
25. PUBLIC PROVIDENT FUND (PPF)
26. PROVIDENT FUND (COMPANY)
27. MONTHLY REMINDERS
28. PASSPORT DETAILS
29. SERVICE REGISTER DETAILS
30. EDUCATIONAL CERTIFICATES
31. MY ACHIEVEMENTS
32. AWARDS RECEIVED FOR THE ACHIEVEMENTS
33. FAMILY BUDGET
34. THINGS TO REMEMBER IN GENERAL
35. DETAILS OF PERSONAL BELONGINGS
36. BIRTH DAYS / WEDDING ANNIVERSARY
37. DETAILS OF PLEDGING
38. ROUTINE MEDICINES TO BE TAKEN DAILY
39. ESSENTIAL MEDICINES WHILE GOING ABROAD
40. DETAILS OF LOANS RECEIVED FROM OTHERS
41. DETAILS OF LOANS GIVEN TO OTHERS
42. DETAILS OF GIFTS PRESENTED TO THE DAUGHTER
43. DETAILS OF GIFTS PRESENTED TO THE DAUGHTER-IN-LAW BY HER PARENTS
44. DETAILS OF GIFTS PRESENTED TO THE GRAND CHILDREN
45. HOROSCOPE DETAILS
46.WILL
47. EYE, ORGAN, BODY DONATION
and etc...
If you want to download this file you visit the link http://www.tiaanovidyashrm.com/diary.aspx

HHO Working Procedure in Boilers

October 06, 2015

HydroGen Installation Procedure




Installation Procedure of HHO system for two wheeler. It is used to save up tp 30% extra mileage and pollution free exhaust.


October 05, 2015

Denora Electrolyzer for Electrochlorinator

Replacement / Refurbishment capacity of Tiaano
We expertise for the replacement or refurbishment of electrolyzers & other spares for electrochlorinators, where the project executed by the following World Leaders, namely …
M/s. Seven Trent De Nora, M/s. Siemens, USA
M/s. Daiki, M/s. Mitsubishi, M/s. Nippon, Japan.
M/s. Cumberland, M/s. Charles Thompson, UK.
M/s. Pepcon, M/s. Electrichlor, USA.
M/s. Sespi, Italy.
M/s. Sal-Chlor, Australia.
& many more unlisted companies too.
Capacity: Single electrolyzer, having the production capacity of available Cl2 per hour is
Minimum size: 500 grams
Maximum size: 250 kilograms
Concentration: 500 ppm to 2500 ppm of Cl2
Design: PPE, CTE, PP&ME
Polarity: Normal
Substrate: Titanium sheet / plate as per ASTM B 265 Gr.1
Titanium tube / pipe as per ASTM B 338/337 Gr.1
Titanium expanded mesh as per ASTM B 265 Gr.1
Titanium rods as per ASTM B 348 Gr.1
Catalyst: Platinum group precious metal mixed oxides
Application: Disinfection

Ti Anode Fabricators Pvt. Ltd.
#48, Noothanchary, Madambakkam, Chennai 126, India.
Phone: + 91 44 2278 1148 | Fax: + 91 44 2278 1362
EmailID: info@tianode.com, tianode@gmail.com | Website: www.ecanode.com



Platinized Anode



2013112421584top.gif
PLATINIZED ANODE
November 26, 2013
20131125195022as.jpg

Special chemical & physical properties like high corrosion resistance, thermal conductivity and catalytic nature, platinum is widely used as electrodes in metal finishing industries. Being a very expensive metal, instead of using solid form, platinum is deposited on the surface of titanium or niobium or tantalum, occasionally on molybdenum by micron level layer. Electrodes [Anodes or Cathodes] are available with hanging hook, frame or band; in the form of sheet, mesh, pipe, wire, rod and custom built. Platinised titanium anode is used in electrolytes having no fluoride. Platinised niobium anodes are used in electrolytes having fluoride, where we need better conduction (its conductivity is three times of titanium) & also it is suitable for Sulphuric acid chromium plating bath operated at current density greater than 75A / dm².
Common Laboratory Beaker anodes are used for Laboratory Plating tests, small batch plating, electrochemical production of organic, inorganic and many other compounds. The common beakers are available in the sizes of 0.5, 1.0, 2.0, 3.0 & 5.0 liters by volume. Standard Platinized Titanium Anodes [PTA] and Platinized Niobium Anodes [PNA] are available for said glass beakers. Anodes are available in the form of expanded mesh with hook, strips with hook and tube for some special applications. Platinised anodes are available with the standard platinum plating layer thickness of 2.5 micron. Plating thick can be increased up to 20 micron depending to the customer’s requirement. PTA anodes are used for the production of chlorates and perchlorate and in plating bath as insoluble anodes. 
Platinised titanium, niobium and tantalum anodes are having the advantages of Low weight because of low surace area due to the high current density - good current resistance; Long life operation - maintenance free; Economical - due to low platinum requirements; High dimensional stability and low resistance; highly suitable as auxiliary anodes of complex geometrical shapes.
Few of its applications are…
  • Metal finishing
  • Beaker anodes
  • Electroforming
  • Cathodic protection
  • Electrochemical sensing
  • Electro winning
  • Metal refining
  • Electrolytic regeneration of chromic acid
  • Electroplating for precious and base metals
  • Electrolytic production of sodium hypochlorite
  • Electro synthesis of Inorganic and organic chemicals
  • Especially production of perchlorates
Visit our site www.ptanode.com to know more about platinized titanium, platinsed niobium, platinum plated tantalum and platinised molybdenum anodes.
201331923269fb.png   2013319232632tw.png Toll Free: 1 800 3000 2333, Phone: +91 044 2278 1148
Email: info@tianode.com Website: www.ptanode.com
Factory Address:
#48, Noothanchary, Madambakkam, Chennai - 600 126, India.


Scale Remover for Cooling Tower

Subscribe Newsletter VIEW AS A WEB PAGE
SCALE REMOVER
Principle:

Tiaano, India ventured and developed “Tiaano-ElSr” for removal or separation of scale/hardness by electrolytic operation. Continuous electrolytic scale removal or hardness removal and onsite disinfectants generation - mitigate the scaling, corrosion, bio-fouling & bacterial infection in cooling tower Water distribution system. In order to overcome the limitations of conventional cooling water treatment (addition of chemicals or by water softening). read more..
Feature:
It produces Oxidants in the water; Oxidants prevents the Corrosion, Bio-fouling, Scaling, Micro-Organism growth & spread of airborne bacteria.
Capacity:
Modular system is designed and available according to the cooling tower chiller capacity like 200 TR, 400 TR, 600 TR, 800 TR, 1000 TR & 1200 TR.

view more offers
view more offers
UNIQUENESS
* Green technology.
* Zero Bleed Loss.
* Low energy Consumption.
* Modular design.
* Zero Toxic Sewer Load.
* Small footprint.
* Easy operation.
* Low maintenance.
* No toxic chemical storage hazard.
view more offers
UNSUBSCRIBE | ABOUT | CERTIFICATE | CONTACT | STAY CONNECTED facebook twitter linkedin
#48, noothanchary, Madambakkam, Chennai 126, India. HP: 91766 25082, Ph: 044 2278 1148, Fax: 044 2278 1362, Email: elsr@tianode.com, Web: www.scaleseparator.com

Titanium Heat Exchanger

Subscribe Newsletter VIEW AS A WEB PAGE
HEAT EXCHANGER
Introduction:
Tiaano design & fabricate cost effective heat exchangers… Shell & tube, Heat exchanging coils, ‘U’ tube bundle, Double pipe, Flot type, having solid, lined or cladded tube sheets.

We use the material for the construction of heat exchangers are … reactive and highly chemical resistance metals of Tantalum, Zirconium, Niobium, Titanium, Nickel and high nickel alloys such as Hastelloy, Monel, Inconel, Duplex & Super duplex steels.

Type of heat exchangers we offer ….. Evaporator, Condenser, Crystallizer (crystalliser), Trim condenser, Contact cooler, Preheater, Cooler, Recuperator, Reboiler, Chiller, Brine heater, Vent condenser, Start-up heater.

We make the exchangers for the medium of… Chlorine, NaOH, Naphtha, Bromine, Acetic acid, Sulphuric acids, Hydrochloric acid, Brine, Seawater and other highly corrosive chemicals.

Industries use our Heat exchangers are… Chloralkali, Power, Pesticides, Insecticides, Naphtha, Refineries, Pharmaceutical, PTA and other Electro-chemical plants.

Range we cover is…

Shell diameter
Tube diameter
Tube length
‘U’ Tubes
Tube sheet type
Tube sheet thick

: Up to 3000 mm
: Up to 76.2 mm
: Up to 12000 mm
: Up to 8000 mm
: Solid, Lined or Cladded
: Max. 100 mm

Code we follow for design … ASME & TEMA

Test we conduct…..

        Pressure

        Shell side
        Tube side

: max. 50 kgs / cm2
: max. 50 kgs / cm2
Non-destructive
Radiographic Test either Gamma or X-Ray
Ultrasonic Flaw Detector
Magnetic Particle Crack Detector
Liquid / Dye penetrant Test Facility.

INSPECTION & QA

* TIAANO
* LLOYDS
* YUV
* EIL
* UDHE
UNSUBSCRIBE | ABOUT | CERTIFICATE | CONTACT | STAY CONNECTED facebook twitter linkedin
#48, noothanchary, Madambakkam, Chennai 126, India. HP: 91766 25082, Ph: 044 2278 1148, Fax: 044 2278 1362, Email: marketing@tianode.com, Web: www.tianode.com